110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA) 110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA)

110 / 220Vdc Power Plant Inverter, Rack-mount Type (2U 3KVA)

Model:SPI-R2 series

Type:
IGBT / PWM Type

Capacity:
3KVA (2U)

Made in:
Taiwan, ROC

Add in inquiry Download

• AC Power for Battery

• ATS

• Automation

• Car Electrification

• Civil and Military Nautical

• Emergency Lighting

• ETC

• Medical Equipment

• Railway Field

• Telecom System

Clean,Highly Regulated Power Supply !


• For Power Plant:110 / 220Vdc DC Voltage.

• 2U / 3U 19" or 23" Rack-mount type.

• 2U / 3U 19" or 23" Open Frame Cabinet.

• Digital Displays.

• Pure Sine Wave Output (THD <3%) Resistive Load.

Bypass Function.

• Advanced Microprocessor.

Inverter mode / UPS mode (Option)

• Built-in Transfer Switch.

• Loading & Temperature Controlled Cooling Fan.

• Output Frequency : 50 / 60Hz Switch.

• Adjustable Output Voltage.

• Reliable Input Surge Protection & EMI Suppression.

• Modularized IGBT infrastructure to ensure better durability.

• Cold start function (DC start) functionality allows unit to operate with battery only.

• RS-232 Interface / Wire Connection to PC.

• Option: SNMP Interface / Dry Contacts / Remote Control.

• Protection : Input Under Voltage, Input Over Voltage, Overload, Short Circuit,

Low Battery Alarm, Over Temperature.

CUSTOMIZATIONS WELCOME

2U 19" Rack Mount Type (3KVA)

Model

A:110V | E: 220V

SPI-R2-1103A

SPI-R2-2203A

 SPI-R2-1103E

SPI-R2-2203E

Outlook Rack Mount  19" 2U
Capacity Continuous O/P Power 3000W
Surge Rating 3200W @ 3 Minutes
3500W @ 3 Seconds
Peak 6000W
DC Input  I/P Voltage  110Vdc  220Vdc  110Vdc  220Vdc 
I/P Voltage Range  90-140Vdc  180-275Vdc  90-140Vdc  180-275Vdc 
Over Voltage Alarm  135.0Vdc 270.0Vdc 135.0Vdc 270.0Vdc 
Over Voltage Cut-off  140.0Vdc 275.0Vdc  140.0Vdc  275.0Vdc 
Under Voltage Alarm  95.0Vdc 185.0Vdc  95.0Vdc 185.0Vdc 
Under Voltage Cut-off  90.0Vdc 180.0Vdc   90.0Vdc 180.0Vdc 
Bypass (AC Input) Nominal Voltage     A: 1 Phase 2W+G, 110Vac (90V - 130Vac)      E: 1 Phase 2W+G, 220Vac (180V - 260Vac)
Frequency (50Hz - 60Hz) ± 3%       (50Hz - 60Hz) ± 3%
Protection Electronic Circuits & AC Circuit Breaker
Bypass Inverter ⇔ Bypass 4 - 6 ms
Inverter⇔Bypas Mode Inverter Mode or UPS Mode by Switch (Option)
AC Output AC Voltage Adjustment   A: 1Phase 2W+G, 100 - 120 Vac (Tune VR)   E: 1Phase 2W+G, 200 - 240 Vac (Tune VR)
Voltage Accuracy < 2% at Linear Load
Frequency 50Hz / 60Hz ± 0.05% (Switch Selectable)
Output Wave Form Pure Sine Wave, <3% THD @ Resistive Load
Output Power Factor 1.0 1.0
Peak Output Current 54A 27A
Efficiency @ Full Load  94% 94% 94% 94%
No Load Current  Draw 0.16A 0.11A 0.28A 0.12A
Protection Protection    Overload, Short Circuit, Reverse Polarity (Fuse), Input Under Voltage,
Input Over Voltage, Over Temperature 
Safety  EN60950-1
EMC FCC class A 

EN55022: 2006, Class A

EN55024:1998+A1:2001+A2:2003

EN61000-3 -2: 2006

EN61000-3-3: 1995+A1:2001+A2-2005

Indicator Digital Display OVP, UVP, OTP, OLP, VAC, AMP, WATT, VDC, TEMP, Hz
Communication Interface Control Unit 

RS-232C with Baud Rate 2400, 4800, 9600, 19200 (Switch Selectable)
Option-1: SNMP Interface
Option-2: Dry Contact: OVP, UVP, OTP, OLP 

Remote Control Unit Optional Can't Support Optional Can't Support
Environment Operating Temperature -20°C ~ 50°C 
Storage Temp. Range -30°C ~ 70°C 
Relative Humidity 0~90%, non-condensing
Cooling Air Forced Fan Loading & Temperature Controlled Cooling Fan
Mechanical Dimension W424 * D445 * H88mm
Net Weight 14.3kgs

* All specifications mentioned above are subject to change without prior notice.

CUSTOMIZATIONS


► HOT STANDBY

► SNMP Interface

► Dry Contacts

► Remote Control

Introduction


110 / 220Vdc 19" or 23" Power Plant (Railway) Inverter, Rack-mount Type is designed for long “MTBF” and continue provide manageable and dependable AC power for network demands.
Featuring an integrated utility bypass function, pure sine wave output and low EMI / RFI emissions, SPI-R2 series Telecom Inverters are well equipped for Telecom and other demanding critical applications.

An intelligent microprocessor-based control and smart software for power management include alerts on the LED display interface that ensure safety and reliability.
A SNMP option is available; and would allow the user remote communication access to the inverter. SPI-R2 Series Power Inverters are among the most reliable systems available for electricity and other demanding critical applications.